CA780 CABLEIZER Metallic Cable Analyzer
The CA780 is the affordable answer to equipping the Installer, Service Technician, Trunk Technician and construction personnel. Never has such a complete cable analyzer as the CA780 combined the ease-of-use with high accuracy and portability
Overview
The CA780 CABLEIZER Metallic Cable Analyzer — Quickly and easily locate defects in all metallic cables with a highly sensitive analyzer and easy-to-read LCD display!
The CA780 locates even minor faults due to superior sensitivity. Broken or damaged shielding and loose or corroded connectors can be easily located. The CA780 combines the ease-of-use with high accuracy and portability.
The CA780 is a TDR (Time Domain Reflectometer); measurements include: cable length, VOP (velocity of propagation), impedance, VSWR (ratio of maximum voltage to minimum voltage on the cable), Delta distance and Delta return loss. Cable signature displays may be stored in memory and later recalled for reference or printed directly to your serial compatible printer.
Features
Specifications
| MEASUREMENT FUNCTIONS | |
| Cable Length: | |
| Maximum Range: | 65,000 feet at VOP = .99 |
| 35,000 feet at VOP = .60 | |
| Resolution: | 0.1 foot from 0.0 to 99.9 feet |
| 1 foot from 100 to 999 feet | |
| 10 feet from 1000 to 9.99 k feet | |
| 100 feet from 10.0 k feet to 65.0 k feet | |
| Accuracy: | ± 0.01%, ± 0.5 feet, ± 1 count |
| < 0.5 foot from 0.0 to 99.9 feet | |
| < 1.7 feet from 100 to 999 feet | |
| < 11 feet from 1000 k to 9.99 k feet | |
| < 100 feet from 10.0 k feet to 65.0 k feet | |
| VOP: | |
| Range: | 30% to 99% on 10 to 1000 feet of cable |
| Resolution: | 1% |
| Accuracy: | ± 1.0% |
| Z (Impedance): | |
| Range: | 30% to 99% on 10 to 1000 feet of cable |
| Resolution: | 1% |
| Accuracy: | ± 1.0% |
| VSWR: | |
| Range: | 1.000 to 99 |
| Resolution: | 0.001 from 1.000 to 1.199 |
| 0.01 from 1.20 to 1.99 | |
| 0.1 from 2 to 9.9 | |
| 1.0 from 10 feet to 99 | |
| Accuracy: | 1% from 1.000 to 1.199 |
| 2% from 1.20 to 1.99 | |
| 5% from 2.0 to 9.9 | |
| 10% from 10 to 99 | |
| DELTA Distance: | |
| Resolution: | 1 pixel; one pixel = Horizontal magnitude divided by 50 |
| Accuracy: | ± 0.01%, ± 0.5 feet, ± 1 pixel |
| DELTA Return Loss: | |
| Sensitivity: | >65 dB |
| Resolution: | 0.1 dB from 0 to 9.9 dB RTL |
| 1.0 dB from 10 to >65 dB RTL | |
| Accuracy: | ± 0.5 dB from 0.0 to 9.9 dB |
| ± 1 dB from 10 to 30 dB | |
| ± 3 dB from 30 to 65 dB | |
| GENERAL | |
| Power Requirements: | |
| Battery Life: | >6 hours continuous |
| Battery Life: | >4 hours (with display light) |
| Battery Saver Time-out: | 10 minutes nominal |
| Battery Charge Time: | 12 - 14 hours |
| Charger: | 13.8 Volt at 700 mA |
| Environmental: | |
| Operating Temperature: | -0 to +120/Deg. F |
| Storage Temperature: | -40 to +150/Deg. F |
| Humidity: | 0 to 90% (non-condensing) |
| Watter Resistant: | Water on any surface (not submersible) |
| Size: | 8" H x 12" W x 8" D |
| Weight: | < 10 lb. |
| Display: | 128 x 240 pixel LCD (2.5: x 4.5") |
| Input/Output: | |
| Connector: | 50W, female, BNC |
| Protection: | 200 V DC + AC peak DC to 400 Hz |
| Powered Cable Detection: | ± 4 V DC or AC peak DC to 400 Hz |
| Output Pulse: | |
| Short: | 2 nSec |
| Medium: | 10 nSec |
| Long: | 100 nSec |
| X Long: | 1000 nSec |
| Amplitude: | -5.0 V peak (-8.0 V peak on 2 nSec pulse) |
| Width: | 50% at 1/2 amplitude |
| Shape: | 1/2 sine wave |
| phone 1.800.736.2673 | International 1.605.339.0100 |