LC103 Rezolver In-Circuit Capacitor/Inductor Analyzer
Resistors, diodes and transistors can be tested in circuit saving lots of time. Why not capacitors and inductors? Reliable in-circuit capacitor and inductor analyzing is plagued by parallel components and circuit paths. Sencore has developed the analyzing technology to make in-circuit capacitor and inductor testing reliable.
Overview
The LC103 ReZolver™ Capacitor and Inductor Analyzer takes the guesswork out of capacitor and inductor testing. The ReZolver™ is a complete, automatic, microprocessor-controlled analyzer ideally suited for service, maintenance, or large volume testing in a lab or incoming inspection.
The ReZolver™ gives you the ability to accurately pinpoint defective capacitors without removing them from the circuit. Using exclusive tests, the ReZolver™ measures the capacitor's value and ESR, checks for parallel components that may otherwise disrupt the measurements, and gives a GOOD/BAD/SUGGEST REMOVAL evaluation.
Dynamically analyze capacitors out-of-circuit for all four failure modes: value (to 20 Farads), dielectric absorption (D/A), leakage (up to 1000 applied volts) and equivalent series resistance (ESR).
Features
– Value from 1 pF to 20 F
– Equivalent series resistance
– Leakage with up to 1,000 volts applied
– Dielectric absorption
– Values from 0.1 µH to 20 H
– Opens or shorts
– Even one shorted turn with patented “Ringer” test
Specifications
| In-Circuit Tests: Dynamic in-circuit tests to determine whether the component is good or bad. | |
| Inductor Range: | 3.18 uH to 3.18 H |
| Capacitor Range: | 0.002 uF to 20,000 uF |
| Capacitor Value: | |
| Range: | 1 pF to 20 F |
| Accuracy: | ± 1%; ± 1 pF, ± 1 digit for values to 1990 uF; ± 5%, ± 0.1% of range full scale for values from 2000 uF to 20 F |
| Equivalent Series Resistance (ESR): | |
| Accuracy: | ± 5%, ± 1 digit |
| Capacitor Range: | 0.01 uF to 20 F |
| Dielectric Absorption: | |
| Accuracy: | ± 5%, ± 1 count |
| Capacitor Range: | 0.01 uF to 20 F |
| Capacitor Leakage: (Flyback & IHVT) | |
| Accuracy: | ± 5%, ± 1 digit |
| Applied Voltage: | 1.0 to 1000 volts |
| Inductor Value: | |
| Range: | 0.1 uH to 20 H |
| Accuracy: | ± 2%, ± 1 digit, ± 0.1 uH |
| Inductor Ringing: | |
| Accuracy: | ± 1 count on readings between 8 and 13 rings |
| Inductor Range: | 10 uH and larger, non-iron core |
| General: | |
| AC Power: | 105 to 130 VAC, 60 Hz |
| Size: | 6" x 9" x 11.5" (HWD) |
| Weight: | 6.0 lbs. without battery, 7.6 lbs. with battery |
| phone 1.800.736.2673 | International 1.605.339.0100 |